IPX9K: Declaration of conformity + IPX9K marking protection rating
Option for dual safety redundant systems: two Wheatstone Bridges (350ohm) and two cables
Technical Features :
RATED OUTPUT
2 mV/V +/- 0.1%
TEMPERATURE EFFECT ON ZERO
0.005 % / °C
TEMPERATURE EFFECT ON SPAN
0.003 % / °C
COMPENSATED TEMPERATURE RANGE
- 10°C / + 50°C
OPERATING TEMPERATURE RANGE
- 20°C / + 70°C
CREEP AT NOMINAL LOAD AFTER 4 HOURS
0.03 %
MAX SUPPLY VOLTAGE WITHOUT DAMAGE
15 Volt
INPUT RESISTANCE
700 ohm +/- 3
OUTPUT RESISTANCE
700 ohm +/- 5
ZERO BALANCE
+/- 1 %
INSULATION RESISTANCE
> 10000 Mohm
SAFE OVERLOAD (% of Full Scale)
150 %
ULTIMATE OVERLOAD (% of Full Scale)
> 300 %
DEFLECTION AT NOMINAL LOAD
0.4 mm
Water protection when cleaning high pressure / steam jet (Test: pressurized hot water is sprayed from a distance of 150 mm). Water pressure 100 bar; temperature 80 ° C; test duration 250 seconds (Reference standard DIN 40050-9).